欢迎您访问:瑞昌明盛自动化设备有限公司,我司将竭诚为您服务!
PILZ 30V4060现货卡件模块工控备件

主页 > 产品中心 > RELIANCE

PILZ 30V4060现货卡件模块工控备件

类目:RELIANCE
型号:PILZ 30V4060现货卡件模块工控备件
全国服务热线:15270269218
手机:15270269218
微信:15270269218
QQ:3136378118
Email:3136378118@qq.com

在线咨询
产品详情


CP60-CPU CP60 CP40B-CPU CP40B   工控产品  自动化设备

CP60-CPU CP60 CP40B-CPU CP40B   工控产品  自动化设备

产品均非实价,询价请联系商家。
【主营产品】

贝利Bailey。Allen-Bradley。福克斯波罗Foxboro。

DCS  PLC  伺服系统 机器人系统 配件。Schneider施耐德。艾默生EMERSON。XYCOM。Woodward伍德沃德。西屋Westinghouse。Honeywell霍尼韦尔。WEStation系统备件。

 

英维思Triconex。Motorola摩托罗拉。罗克韦尔Rockwell。ABB。XYCOM。本特利Bently。GE通用电气。Yaskawa安川。。Bosch Rexroth博世力士乐。Yokogawa横河。Siemens(西门子)。Reliance。Modicon莫迪康

With the vigorous development of shipbuilding industry, the application of large span and large tonnage shipbuilding beam gantry crane is more and more widely. In view of the working conditions and control technical requirements of this kind of crane, the requirements for its electrical control performance, speed adjustment accuracy, safety and reliability are higher and higher. With the increasing development of electrical control technology, frequency conversion speed regulation, encoder deviation correction and PLC complex operation are gradually applied in large span and large tonnage cranes. The following is a systematic description of the design scheme of mg300t * 46m double girder gantry crane electrical system.
ABB Inverter supports Modbus RTU protocol when it works normally. As a slave station of Modbus RTU, Siemens 300plc of monitoring center system supports PROFIBUS DP protocol. As a master station of DP, the two protocols are different, so data exchange can not be realized by direct communication. Data exchange between different protocols can only be realized by a third-party protocol conversion module. In this case, the general serial port to profibusdp gateway pm-160 developed and produced by Shanghai Sibo Automation Technology Co., Ltd. is used to realize the conversion of ModbusRTU protocol to profibusdp protocol, so as to realize the real-time monitoring and control of ABB inverter output frequency, start stop, forward and reverse parameters through Siemens 300plc, Ensure that the monitoring center system can monitor the status of ABB Inverter remotely and control the start and stop of inverter.Most of the stacking shapes of robots need robot engineers to go to the site to program and debug according to the requirements of stacking shapes. Each stacking shape needs an independent program, which is time-consuming and laborious. And the requirements for debugging personnel are high, people without programming skills can not complete debugging. As a standard or semi-standard equipment company, it needs a set of standard palletizing procedures, and it can complete palletizing debugging without professional robot engineers.