欢迎您访问:瑞昌明盛自动化设备有限公司,我司将竭诚为您服务!
FBM203 P0914SV

主页 > 产品中心 > RELIANCE

FBM203 P0914SV

类目:RELIANCE
型号:FBM203 P0914SV
全国服务热线:15270269218
手机:15270269218
微信:15270269218
QQ:3136378118
Email:3136378118@qq.com

在线咨询
产品详情

*主营销售:进口DCS、PLC控制系统备品备件和大型进口系统模块备件公司

①Allen-Bradley(美国AB)系列产品》

②Schneider(施耐德电气)系列产品》

③General electric(通用电气)系列产品》

④Westinghouse(美国西屋)系列产品》

⑤SIEMENS(西门子系列产品)》

⑥销售ABB Robots. FANUC Robots、YASKAWA Robots、KUKA Robots、Mitsubishi Robots、OTC Robots、Panasonic、Robots、MOTOMAN Robots。

⑦estinghouse(西屋): OVATION系统、WDPF系统、MAX1000系统备件。

⑧Invensys Foxboro(福克斯波罗):I/A Series系统,FBM(现场输入/输出模块)顺序控制、梯形逻辑控制、事故追忆处理、数模转换、输入/输出信号处理、数据通信及处理等。Invensys Triconex: 冗余容错控制系统、基于三重模件冗余(TMR)结构的zui现代化的容错控制器。

⑨Siemens(西门子):Siemens MOORE, Siemens Simatic C1,Siemens数控系统等。

⑩Bosch Rexroth(博世力士乐):Indramat,I/O模块,PLC控制器,驱动模块等。

◆Motorola(摩托罗拉):MVME 162、MVME 167、MVME1772、MVME177等系列。
采购美国、德国、法国、意大利等欧盟国家工控产品、备品备件

The parameter setting of PID is the core content of the control system design of injection molding machine. It is to determine the pressure, speed, temperature PID control proportion coefficient, integration time and differential time according to the characteristics of injection molding process. There are many methods to set PID control parameters, which are summarized in two categories: one is theoretical calculation and setting. It is mainly based on the mathematical model of the action system of the injection molding machine, and the control parameters are determined by theoretical calculation. The calculation data obtained by this method may not be directly used, but also must be adjusted and modified by the actual action of injection molding machine. The second is the setting method of the action process of the injection molding machine. It mainly relies on the experience of the injection molding machine action control, and directly adjusts the pressure, speed and temperature when the injection molding machine is running. The method is simple and easy to master, and is widely used in the commissioning of the injection molding machine. The engineering setting methods of PID control parameters are mainly critical proportion method, reaction curve method and attenuation method. The three methods have their own characteristics, and their common point is to pass the test, and then adjust the PID parameters according to the experience of injection molding machine debugging. However, no matter which method is adopted, the PID parameters need to be adjusted and perfected in practice. During the field setting of injection molding, we should keep PID parameters in the order of proportion first, then integration and final differentiation. While observing the trend curve of field process value PV, slowly change PID parameters and make repeated trial until the control quality meets the requirements. In the setting of injection molding machine pressure, speed and temperature, we usually turn off integral term and differential term first, i.e. ti is set to infinity and TD is set to zero, so that it can be adjusted as pure proportion. The initial scale is set according to the empirical data, and the proportion is controlled slowly according to the PV curve, so that the system can achieve the PV curve with 4:1 attenuation oscillation, and then add the integral function. Before the integral action, the proportion should be increased to about 1.2 times of the original. The integration time ti is adjusted from large to small until the system obtains the PV curve of 4:1 attenuation oscillation again. If differential action is needed, the differential time is calculated according to td= (1/3-1/4) Ti. Then the scale can be adjusted to the original value or smaller, and then the differential time can be adjusted from small to large until the PV curve reaches satisfaction. One thing to note is that in the process of trial, if Ti and TD are to be changed, the ratio should be kept unchanged. Before finding the best setting parameters, we should analyze the trend of PV value curve, judge the change of disturbance, and then make a trial slowly. If the optimal setting parameters or parameters cannot be found after many times, and the injection molding process must be more accurate, the effectiveness of single loop PID control should be considered, and more complex PID control should be selected. It is worth noting: after the PID optimal setting parameters are determined, it can not be explained that it is always the best. When the fundamental change occurs due to external disturbance, for example, the pressure proportional valve is adjusted and cleaned, and the heating ring is replaced. In fact, if the temperature is to be precisely adjusted, different products, different back pressure and thermal inertia are different, all of them need to be adjusted! We must readjust the optimal parameters according to the needs, and it is also an important link to ensure the effectiveness of PID control. Of course, in the actual injection molding production only a period of time to carry out a verification can!