BENTLY 1900/65A-01-01-01-00-00工控卡件模块监测器现货

主页 > 产品中心 > RELIANCE

BENTLY 1900/65A-01-01-01-00-00工控卡件模块监测器现货

类目:RELIANCE
型号:1900/65A-01-01-01-00-00
全国服务热线:15270269218
手机:15270269218
微信:15270269218
QQ:3136378118
Email:3136378118@qq.com

在线咨询
产品详情
BENTLY  1900/65A-01-01-01-00-00工控卡件模块监测器现货 BENTLY  1900/65A-01-01-01-00-00工控卡件模块监测器现货
瑞昌明盛进出口贸易有限公司
主营DCS控制系统备件,PLC系统备件及机器人系统备件,
优势品牌:Allen Bradley、BentlyNevada、ABB、Emerson Ovation、Honeywell DCS、Rockwell ICS Triplex、FOXBORO、Schneider PLC、GE Fanuc、Motorola、HIMA、TRICONEX、Prosoft等各种进口工业零部件

BENTLY  1900/65A-01-01-01-00-00工控卡件模块监测器现货 BENTLY  1900/65A-01-01-01-00-00工控卡件模块监测器现货 BENTLY  1900/65A-01-01-01-00-00工控卡件模块监测器现货

BENTLY  1900/65A-01-01-01-00-00工控卡件模块监测器现货

希尼尔水库工程包括:主、付坝、引水闸、引水渠、放水闸、分水闸(东干渠与西干渠)及附属设施等。坝体为砂砾石均质坝,坝顶宽6m,上游坝坡1∶2.5,下游坝坡1∶2;坝体坝体防渗采取斜铺复合膜(两布一膜)结构,其中膜厚0.75mm,无纺布规格为200g/m2;坝上游护坡设计为砼板护坡,砼板厚15-22cm,混凝土设计标准为C30 W8 F300。坝基防渗,根据地质情况的不同,分别采取PE塑膜、塑性混凝土防渗墙、水泥土防渗墙三种不同形式的防渗方式。
3、希尼尔水库闸门自动监控系统设计
3.1系统设计目标 (1)实现3孔闸门的远程控制和现地控制相结合; (2)完成实时数据采集、水文数据整编、定时打印报表和运行参数; (3)闸门开度控制精度为±1cm; (4)具有闸门防卡死、越位、启闭机过负荷等保护报警功能; (5)系统故障自诊断。 3.2系统概况 系统以PLC可编程序控制器作为现地控制中心,采用原有的常规手动操作启闭机功能,同时增设远程接口控制电气回路,接受PLC可编程程序控制器的动作。系统高层为计算机监控系统,它包括监控计算机、服务器、集线器、以太局域网,实现各计算机之间的通讯。控制层内由一台PLC可编程序控制器来完成,它负责闸门开启度、水位(东干渠、西干渠与放水渠)等水文数据的实时采集,由于水闸的自动化控制系统在距离水闸大约700m的水库中心调度室监控,系统的现地PLC控制单元与上位监控计算机的通讯采用光纤通讯,采用直接与Modbus Plus网中的PLC通讯存取信息的方式,将采集数据传输给监控计算机,输出模块控制闸门的动作。这种结构的系统更可靠,在上位机出现故障时,也不影响现地控制的操作。 3.3控制模式 3.3.1远程手动方式 当控制模式选择远程点动方式,在监控计算机选择点动操作,在工控机或上位机上用鼠标单击所需要动作的闸门,进行上、下、停操作。 3.3.2现场手动操作方式 当控制模式选择为现场手动操作方式,则在任何情况下现场控制箱选择现场手动操作时,远程对此闸门的操作无效,现场测控屏上可以进行常规的手动按钮操作方式。 3.4 PLC选型 系统控制对象为闸门,由于远程控制,操作人员不在启闭机现场,为确保系统安全,实现闸门启闭机的上、下、停操作以及显示工作状态,根据系统的要求,PLC主要使用的模块有: ①DI模块用于闸门启闭机的数字量采集,监控系统的运行状态;②DO模块用于继电器输出,控制闸门的运行;③AI模块监控闸门开度以及启闭电动机电压、电流。 根据3孔闸门实现远程控制系统数据采集和监控的特点,选用Modicon Tsx Micro可编程系列控制器,采用模块化结构设计,CPU单元型号可选用TSX37-22,此PLC可编程系控制器是专为OEM而设计的高性能PLC,具有加固性、紧凑性及可扩展性等特点。其开关量I/O
大可至256点,同时具备模拟量I/O、高速计数以及网络通讯等扩展模板。 3.5编程及程序运行 采用施耐德公司的PL7
编程软件
,用梯形图方式,对闸门控制进行编程,从程序的内容上分2种形式的程序设计。 3.5.1开环程序设计 对闸门的点动操作、手动操作、定位操作都采用开环程序设计。点动操作、手动操作作为非定量操作,定位操作为给定闸门上、下运行时,闸门的惯性及闸门的刹车性能不一样,所以编程时,要考虑定位控制的补偿问题。 3.5.2故障自诊设计 由于本系统为远程集中控制,闸门操作人员不在现场,如闸门故障发生,要及时停止启闭机的运行,并能够对故障信号、事故信号实时报警显示,否则将发生严重事故。启闭机主要有以下的故障类型:①闸门卡死故障。当闸门下降时,水闸下有杂物顶住平板钢板闸门,闸门不能继续下降。②闸门运行超限故障。闸门一般有闸门槽,不能超过此高度,否则闸门出槽,此为超限故障。③闸门过载故障。通过对
电机
电流的监测,当出现比较大电流时,说明电机过载。error detection ability, so as to realize sil3 / Cat4. The new safety design of Shengjuan zaizao is uniformly applied to the manufacturer's robot unit, eliminating a large number of contactors, relays and complex interconnection lines previously required. Some sections adopt all necessary safety functions and use distributed control and PLC cabinet for separate commissioning. Since the cable distance between the islands is shorter than the distance previously connecting all I / O equipment to the main panel, the installation time is reduced. Diagnostic details from the touch panel help quickly resolve operational faults. S7315f safety PLC with fault tolerance and standard distributed I / O is used to realize all safety functions. In this implementation, when maintaining free access to the standard code, the key consideration of the manufacturer is the ability to "lock" the safety function. The configuration and programming of safety technology are fully embedded in the STEP7 programming environment and distributed safety software. It also includes prefabricated components from f-library (for application blocks such as emergency stop circuit and discharge control). Using this programming environment, the program is easy to change, so it is more flexible than permanently wired systems. Because profisafe technology allows the use of third-party products, fault-tolerant connection to adjacent factories with conventional Profibus Technology and its bus coupler can be realized simply, safely and flexibly. In addition to enhanced security, higher availability and improved diagnostics generate improved yield enablers through PROFIBUS, which can bring a huge return on investment. The paint workshop reconstruction project should be compatible with the changes of North American safety standards. The project manager determines some standards that must be met, including:?